MN/CiLink.IOM

3–11

3.3.4

Main Menu

Æ Current Fault Status

The currently selected transceiver is the unit that will be polled for status
information in the

Current Fault Status XCVR#

selection box:

XCVR1

is the default selection and

XCVR2

is not selectable if CiLink is set to operate under

standalone (non-redundant) system parameters (see

Configuration

Æ

System Type

for detailed

information).







XCVR Internal Voltages

– The transceiver unit monitors

the six internal DC voltages: 24, 20, 12, 10, +5 and –5 for
the currently selected transceiver. The monitor circuitry
will display a fault if any of these voltages are ±10% out
of range.

Lock Detects

– The transceiver monitors the four phase

lock loops (PLLs) for each transceiver. A fault is
displayed for any and each PLL that is not locked.

Currents (mA)

and

Temps

– The Fan and LNA are

monitored for excessive and low currents. A fault is
displayed if these currents are out of their prescribed
window.

If the temperature rises out of specification for the transceiver, a fault will appear in the

HeatSink

field.


As the heat sink temperature continues to rise, the transceiver will automatically disable
the FET amplifiers and display a

ShutDn

(shutdown) fault.

Processor

– The

Chksum

(checksum), IIC Bus, and

Battery

are monitored for proper

operation and will display a faulted condition when the processor system is not
functioning properly.


Tap

[Get Data]

to

query

the selected transceiver and

refresh

the information parameters.

Otherwise, tap

[ok]

to

return

to the

Main Menu

from the

Current Fault Status

screen.

IMPORTANT

The information provided on the Current Fault Status screen furnishes
information on a
status only basis. All information furnished on this screen is
refreshed each time the
Current Fault Status screen is selected, if the currently
selected transceiver is changed, or if the

[Get Data]

icon is selected.

Each shaded status window on this screen displays the parameter’s active status as
operating either within operational limits
[OK] or in faulted conditions [FT].