beautypg.com

2 main menu ( configuration ( signal path, 2 main menu æ configuration æ signal path – Comtech EF Data CiLink User Manual

Page 28

background image

CSAT-5060/XSAT-7080 Transceiver iPAQ Link

Revision 2

Operations

MN/CiLink.IOM

3–6

3.3.2.2 Main Menu

Æ Configuration Æ Signal Path

The currently selected transceiver is the unit that will be polled for status
information in the

Signal Path

configuration

XCVR#

selection box:

XCVR1

is the default selection and

XCVR2

is not selectable if CiLink is set to operate under

standalone (non-redundant) system parameters (see

Configuration

Æ

System Type

for detailed

information).

The status-only

ONLINE/OFFLINE

field to the right of the

XCVR#

selection box indicates the

active line status of the currently selected transceiver.

The Up Converter and Down Converter sections allow the user to view and/or change the
following transceiver parameters:

TX

status-only – This is a summary of the

Amp=On

,

Mute=Off

and no faults present (Up Converter section)

RX

status-only – This is a summary of the

Mute=Off

and no

faults present (Down Converter section)

Amp [On/Off]

▼ – The user can change the state of the

amplifiers in the currently selected transceiver to

On

or

Off

.

Mute [On/Off]

▼ – The user can mute the output of the

currently selected transceiver when set to

On

.

Attenuation

– Both transmit and receive attenuation are

user-configurable. The TX attenuation can be selected
between 00.00 dB and 25.00 dB in 0.25 dB increments; the
RX attenuation can be selected between 00.00 dB and 20.00
dB in 0.25 dB increments.

Frequency

– Both transmitter and receiver frequencies are user-configurable. The TX or

RX frequency can be selected to any frequency divisible by either 1.0 MHz or 2.5 MHz in
the valid TX or RX frequency range.

IMPORTANT

The Up and Down Converter Frequency and Attenuation settings can only be
changed if the currently selected XCVR is ONLINE. Use the Windows Keypad
to manually enter new values for these settings in the provided data fields.

Tap

[Set Data]

to

save

the updated configuration selections. Otherwise, tap

[ok]

to

return

to the

Main Menu

from the

Configuration

Æ Signal Path

screen without saving any changes.

Å

Keypad