Operations

MN/CiLink.IOM

3–5

3.3.2.1 Main Menu

Æ Configuration Æ System Type

There are two modes of operation when using CiLink:

Standalone

and

1:1

.

Standalone

– The standalone mode is typically selected

when CiLink is used with a single transceiver.

1:1 (One-for-One)

– The 1:1 mode is selected when two

transceivers are used in a redundant system configuration
with a redundant controller box (RED box – see Figure 2-6
on page 2-3). This mode can allow the user to control the
online / offline transceiver through the RED box. Refer to
page 3-9 to review the

Redundancy Controller

control and

operating parameters.


When the

1:1

system is selected, the major difference in CiLink’s

functionality is the ability to select

XCVR1

or

XCVR2.

When

selecting

XCVR1

, the parameters and controls are displayed for

the first transceiver. Alternately, when

XCVR2

is selected, the

corresponding parameters and controls are displayed for the
second transceiver.





Select the desired System Type, then tap

[Set Data]

to

save

the active system setup selection.

Otherwise, tap

[ok]

to

return

to the

Main Menu

from the

Configuration

Æ System Type

screen.

The Redundancy Controller configuration mode
(Main Menu

Æ Configuration Æ Redundancy

Controller)

is selectable only if CiLink has been

configured as a 1:1 system.

If a 1:1 System Type is selected in absence of a
redundant system (i.e., when a standalone unit
is connected to the handheld device), an error
message displays:

See page 3-9 for more information.