Comtech EF Data CLC-10 User Manual
Page 52
CLC-10 Comtech LPOD Controller Handheld Terminal M&C Accessory
Revision 3
Serial-Based M&C using the CLC-10
MN-CLC10
3–20
Parameter Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are printable ASCII characters)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to Query
(Target to
Controller)
IP Address
IPA=
18 bytes
Command or Query.
Sets or returns the IP address and network prefix for the 10/100 BaseT Ethernet management port, in the form
xxx.xxx.xxx.xxx.yy, where:
xxx.xxx.xxx.xxx is the IP address, and
yy is the network prefix (8-30)
Default value: 192.168.001.004.24
Note: Changing the IP address through the Telnet interface requires the user to power cycle the unit, and then
restart a new Telnet session with the new IP address. The IP address that you type into the Telnet client
software does not include the range parameter so it would be: 192.168.1.4
Example: <1/IPA=192.168.001.004.24’cr’
>0001/IPA=’cr’’lf’
IPA=
IPA?
IPA*
IPA#
IPA?
IPA=
xx.xxx.xxx.xxx.yy
(See Description of
Arguments)
Gateway Address
IPG=
15 bytes
Command or Query.
Sets or returns the Gateway IP address for the 10/100 Base Tx Ethernet management port, in the form
xxx.xxx.xxx.xxx.
Default value: 192.168.001.005
Example: <1/IPG=192.168.001.005’cr’
>0001/IPG=’cr’’lf’
IPG=
IPG?
IPG*
IPG?
IPG=xxx.xxx.xxx.xxx
Initialize Statistics
Pointer
ISP=
None
Command only.
Resets internal pointer to allow RNS? queries to start at the beginning of the stored statistics log.
Example: <1/ISP=’cr’
>0001/ISP=’cr’’lf’
ISP=
ISP?
ISP*
N/A
N/A
LNB Current
Source
LCS=
1 byte
Command or Query.
Sets or returns the LNB current source in the form x, where:
x= 0,1,2,3 or 4:
0=Disable (default value)
1=Enable (18V 22kHz Disabled – Note 2)
2=18V 22kHz Enabled (Note 2)
3=13V 22kHz Disabled (Note 2)
4=13V 22kHz Enabled (Note 2)
Notes:
1. LCS must be enabled before the LNB current can be calibrated
2. This feature is available on multi-band units only.
Example: <1/LCS=1’cr’
>0001/LCS=’cr’’lf’
LCS=
LCS?
LCS*
LCS?
LCS=x
(See Description of
Arguments)