beautypg.com

Comtech EF Data CLC-10 User Manual

Page 52

background image

CLC-10 Comtech LPOD Controller Handheld Terminal M&C Accessory

Revision 3

Serial-Based M&C using the CLC-10

MN-CLC10

3–20

Parameter Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are printable ASCII characters)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to Query

(Target to

Controller)

IP Address

IPA=

18 bytes

Command or Query.

Sets or returns the IP address and network prefix for the 10/100 BaseT Ethernet management port, in the form

xxx.xxx.xxx.xxx.yy, where:

xxx.xxx.xxx.xxx is the IP address, and

yy is the network prefix (8-30)

Default value: 192.168.001.004.24

Note: Changing the IP address through the Telnet interface requires the user to power cycle the unit, and then

restart a new Telnet session with the new IP address. The IP address that you type into the Telnet client

software does not include the range parameter so it would be: 192.168.1.4

Example: <1/IPA=192.168.001.004.24’cr’

>0001/IPA=’cr’’lf’

IPA=

IPA?

IPA*

IPA#

IPA?

IPA=

xx.xxx.xxx.xxx.yy

(See Description of

Arguments)

Gateway Address

IPG=

15 bytes

Command or Query.

Sets or returns the Gateway IP address for the 10/100 Base Tx Ethernet management port, in the form

xxx.xxx.xxx.xxx.

Default value: 192.168.001.005

Example: <1/IPG=192.168.001.005’cr’

>0001/IPG=’cr’’lf’

IPG=

IPG?

IPG*

IPG?

IPG=xxx.xxx.xxx.xxx

Initialize Statistics

Pointer

ISP=

None

Command only.

Resets internal pointer to allow RNS? queries to start at the beginning of the stored statistics log.

Example: <1/ISP=’cr’

>0001/ISP=’cr’’lf’

ISP=

ISP?

ISP*

N/A

N/A

LNB Current

Source

LCS=

1 byte

Command or Query.

Sets or returns the LNB current source in the form x, where:

x= 0,1,2,3 or 4:

0=Disable (default value)

1=Enable (18V 22kHz Disabled – Note 2)

2=18V 22kHz Enabled (Note 2)

3=13V 22kHz Disabled (Note 2)

4=13V 22kHz Enabled (Note 2)

Notes:

1. LCS must be enabled before the LNB current can be calibrated

2. This feature is available on multi-band units only.

Example: <1/LCS=1’cr’

>0001/LCS=’cr’’lf’

LCS=

LCS?

LCS*

LCS?

LCS=x

(See Description of

Arguments)