beautypg.com

Comtech EF Data CLC-10 User Manual

Page 49

background image

CLC-10 Comtech LPOD Controller Handheld Terminal M&C Accessory

Revision 3

Serial-Based M&C using the CLC-10

MN-CLC10

3–17

Parameter Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are printable ASCII characters)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to Query

(Target to

Controller)

Set RTC (Real-

Time-Clock) Date

E

DAT=

6 bytes

Command or Query.

Sets or returns the real-time clock date in the form mmddyy, where;

dd=day of the month, from 01 to 31,

mm=month of the year, from 01 to 12

yy=year, from 00 to 96 (2000 to 2096)

Example (date=April 24, 2003):

<1/DAT=042403’cr’

>0001/DAT=’cr’’lf’

DAT=

DAT?

DAT*

DAT?

DAT= mmddyy

(See Description of

Arguments)

Set RTC (Real-

Time-Clock) Date

DAY=

6 bytes

Command or Query.

Sets or returns the real-time clock date in the form ddmmyy, where;

dd=day of the month, from 01 and 31,

mm=month of the year, from 01 to 12

yy=year, from 00 to 99 (2000 to 2099)

Example (date=April 24, 2003):

<1/DAY=240403’cr’

>0001/DAY=’cr’’lf’

DAY=

DAY?

DAY*

DAY?

DAY= ddmmyy (See

Description of

Arguments)

Enable Statistics

Averaging

ESA=

1 byte

Command or Query.

Enables or Disables averaging of statistics data at a rate of once per second for 10 seconds, in the form x,

where:

0=Disable (default value)(see Note)

1=Enable

Note: If Disabled, burst values will be logged instead of averaged values.

Example: <1/ESA=0’cr’

>0001/ESA=’cr’’lf’

ESA=

ESA?

ESA*

ESA?

ESA=x

(See Description of

Arguments)

Enable Statistics

Logging

ESL=

1 byte

Command or Query.

Sets or returns the statistics logging function in the form x, where:

0=Disable (default value)

1=Enable

Example: <1/ESL=1’cr’

>0001/ESL=’cr’’lf’

ESL=

ESL?

ESL*

ESL?

ESL=x

(See Description of

Arguments)