CLC-10 Comtech LPOD Controller Handheld Terminal M&C Accessory

Revision 3

Serial-Based M&C using the CLC-10

MN-CLC10

3–18

Parameter Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are printable ASCII characters)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to Query

(Target to

Controller)

Enable

Redundancy

Switch Mode

ESW=

1 byte

Command or Query.

Sets or returns the redundancy state in the form x, where:

0=Off (default value)

1=1:1 Redundancy TX (Only TX switch installed)

2=1:1 Redundancy TX + RX (TX and RX switch installed)

5=1:1 Manual redundancy mode (used for debugging, or redundant system setup)(see Note)

Note: Manual redundancy does not support automatic switching, and the offline unit will not poll the online unit

to update its configuration.

Example: <1/ESW=1’cr’

>0001/ESW=’cr’’lf’

ESW=

ESW?

ESW *

ESW?

ESW=x

Retrieve Firmware

Number

N/A

Query only

Returns the firmware type(s) loaded into the unit in the form FW-AAAAAAA B.B.BB DD/MM/YY, where:

FW-AAAAAAA=the firmware part number

B.B.BB=the version number

DD/MM/YY=Day/Month/Year firmware released

Example:

<1/FRW?’cr’

>0001/FRW=

Boot:

FW-0000082 0.0.1a 04/09/08

Bulk1:

FW-0000078 0.0.1a 04/09/08

FW-0000080 0.0.1a 04/09/08

FW-0000081 0.0.1a 04/09/08

Bulk2:

FW-0000078 0.0.1a 04/09/08

FW-0000080 0.0.1a 04/09/08

FW-0000081 0.0.1a 04/09/08

FRW=

FRW?

FRW={CR}Boot:{CR}

abc{CR}Bulki:{CR}ab

c{CR}abc

(See Description of

Arguments)