2.6.2

CLC-10 Display

The CLC-10 features a LED backlit supertwist nematic

display that affords you an expanded viewing angle,

optimal readability in low-light conditions, and realizable

operation in extreme temperature environments (-4° F to

+158° F / -20° C to +70° C). The display provides four content rows, at 20 characters per row,

using the standard U.S. ASCII character set.

2.6.3

CLC-10 –to– SSPA Communication Settings

Sect. 3.4.3 Basic Protocol in Chapter 3. SERIAL-BASED M&C USING THE

CLC-10.

Sect. 4.5.5.3.1 Config | Amplifier in Comtech EF Data’s LPOD Outdoor

Amplifier / Block Up Converter (BUC) Installation and Operation Manual
(CEFD P/N MN-LPOD) or SPOD Outdoor Amplifier Installation and Operation
Manual (CEFD P/N MN-SPODPSX).

Two Technologies, Inc. TechTerm® Technical Reference Manual (2T

Document 15776, available from www.2t.com).

SSPA Configuration: The CLC-10 ships preconfigured for interoperability with the SSPA. The

character format should be 8N1 (8 data bits, no parity, 1 stop bit). The maximum allowable

serial baud rate for the CLC-10 is 9600 bps. In order for the SSPA to properly communicate with

the CLC-10, its serial baud rate must be preset to 9600 baud using the SBR command via the

remote serial interface, or in the Serial section on the SSPA Web Server Interface Config |

Amplifier page.

CLC-10 Configuration: Should there be any reason to reconfigure the CLC-10 for proper

communication with the SSPA, follow these steps:

Step

Task

1

Hold CTRL and SHIFT and press F1 to access the CLC-10 Parameter menu. Alternately, disconnect the

CA-0020526 Serial Interface Cable from the CLC-10 while simultaneously holding the CTRL, SHIFT, and

F3 keys and then reconnect the cable to the CLC-10.

2

The CLC-10’s Parameter menu appears; its first

configurable parameter appears on the top row of the

display, and action prompts are provided on the next three

rows:

To navigate between parameter settings:

Press F2 to move to the NEXT parameter

Press F3 to return to the PREVISION parameter.

Press F1 to CHANGE (edit) the currently selected parameter.