Comtech EF Data CLC-10 User Manual
Page 47
CLC-10 Comtech LPOD Controller Handheld Terminal M&C Accessory
Revision 3
Serial-Based M&C using the CLC-10
MN-CLC10
3–15
Parameter Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are printable ASCII characters)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to Query
(Target to
Controller)
Calibrate LNB
Current
CLC=
none
Command or Query.
Sets or returns, as a reference point, the value of the LNB Current Supply (in mA) in the form xxx.x.
Default value: 000.0
The LNB current alarm point is then determined by the calibrated LNB reference point, and the LNB current window
setting (see LCW command).
Note: this command will return a mode error if the LNB current source output has not been enabled first (see
LCS command).
Example: <1/CLC=’cr’
>0001/CLC=’cr’’lf’
The CLC query will return the value that was stored during the LNB current calibration.
Example: <1/CLC?’cr’
>0001/CLC=xxx.x where xxx.x is the calibrated LNB current value in mA.
CLC=
CLC?
CLC*
CLC?
CLC=xxx.x
(See Description of
Arguments)
Clear Statistics
Log
CSL=
1 byte
Command only.
Clears the statistics log entries. This command takes no arguments.
Example:
<1/CSL=1’cr’
>0001/CSL=’cr’’lf’
CSL=
CSL?
CSL*
N/A
CSL=
Concise Utility
Status
E
N/A
15 bytes
Query only.
Returns the Maintenance status of the unit, response is semicolon delimited, in the form aaaa;bbbbb;ccc where:
aaaa=Remote Unit Address
bbbbb=Remote Baud Rate
ccc=Reference oscillator tuning voltage DAC value (see Note)
Note: ccc is only present if a reference oscillator is installed.
Example:
<1/CUS?’cr’
>0001/CUS=aaaa;bbbbb;ccc;’cr’’lf’
CUS=
CUS?
CUS=x….x
(See Description of
Arguments)