2.2 Rack-Mount Installation
The unit is designed to mount in a standard 19” (48.26 cm) rack cabinet or enclosure. A rack-mount installation
requires 1.75” (4.44 cm) of panel height. The rack-mount will extend approximately 16” (40.64 cm) into the
cabinet.
The environment around the rack mount should be moisture-free with a moderate indoor temperature. There
should also be adequate air ventilation on the sides of the rack mount equipment.
Attach the supplied slide rails to the front and rear of the cabinet and proceed with the power connections.
2.3 Power Connection
The detachable power cords are intended to mate with the AC receptacle/filter at the rear of the unit. The power
cords are designed to be connected to two independent power sources, each providing an AC voltage between
90 and 240V. (Although this is not a requirement, the cords enhance the integrity of the redundancy.)
NOTE: Power can be applied to the unit without the output cables connected.