beautypg.com

1 overview – Comtech EF Data RC-1160 User Manual

Page 18

background image

Introduction

Revision 1

RC-1160 RC-1260 Redundancy Switch Controllers

MN-RC1160RC1260

1–2

1.1 Overview

A complete redundant system consists of:

RC-1160 or RC-1260 redundancy switch controller

Redundant amplifier plate with two or three LNA/LNBs

Interconnect cable up to 1500 feet (457 meters) in length

The redundancy switch controller performs the following functions:

Supplies +14V power to the LNA/LNBs.

Measures LNA/LNB current.

Performs calibration on LNA/LNB current.

Signals a fault with abnormal current deviation.

Sounds audio alarm on fault (can be disabled).

Switches LNA/LNB on a priority basis in auto mode.

Controls waveguide and coaxial switch position.

Provides FORM-A and FORM-C relay contacts for remote status.

Provides a 9-pin EIA-485/-232 serial interface.

Normal/maintenance switch online during servicing.

This manual is related to the following products: