beautypg.com

Aintenance, Nterface – Comtech EF Data CiM-25/600 User Manual

Page 62

background image

CiM-25/600 IP Enabled M&C

Rev. 3

SNMP Interface

CD/CIM25600.IOM

42

3.6 M

AINTENANCE

I

NTERFACE

The default network configuration settings are:

IP:

10.6.30.1

Admin Name:

admin

Admin Password:

1234

The CiM-25 has been designed to allow a user to reset the unit back to the factory default
settings, change the IP Address, and verify the software version. Use the following
procedure to make these changes.

Perform the following steps:

1

Disconnect the CiM-25 from both the interfacing equipment and the Ethernet Network.

2

Connect the CiM-25 to the serial port of a PC using a cable defined below (null cable):

CiM-25 pin 2 to PC pin 3
CiM-25 pin 3 to PC pin 2
CiM-25 pin 5 to PC pin 5

2

3

5

DB

9

2

3

5

DB
9

To CiM-25 Device

(M/F Depending on Unit)

To Computer

(Usually Female)

Figure 1. Null Cable Diagram

3

Power the CiM-25 using the Power Jack connector and an external 5 Vdc power supply.

4

Using a Serial Communication application such as Terminal, ProComm, etc., configure the
PC’s serial port to:

Baud: 19200
Data rate: 8-N-1

Use the procedures in following sections to:

Reset to factory network defaults.

Change network IP Address.

Verify software version.

Change MAC Address.

Change Serial Number.