A.7.97 – Comtech EF Data CiM-25/600 User Manual
Page 141
CiM-25/600 IP Enabled M&C
Rev. 3
SNMP Interface
CD/CIM25600.IOM
121
A.7.97
UNIT
F
AULT
T
RAPS
Name
unitFaultTraps
OID
1.3.6.1.4.1.6247.18.1.9.0.1
Full path
iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).comtech(6247)
.cdm600(18).cdm600Objects(1).trapNotifications(9).trapNotificationsPr
efix(0).unitFaultTraps(1)
Module
CDM600
Parent
trapNotificationsPrefix
Next sibling
unitConfigChangeTrap
Type
NOTIFICATION-TYPE
Status
current
Objects
1
unitFaults
Description
Unit Fault Trap Using unitFaults. (FLT?) FLT=abcde.
Response string: abcde, where:
a = Unit faults:
0 = No faults
1 = Power supply fault, +5 volts
2 = Power supply fault, +12 volts
3 = Power supply fault, -5 volts
4 = Power supply fault, +18 volts
5 = Power supply fault, -12 volts
6 = RAM load fail
7 = Tx synthesizer lock
8 = Rx synthesizer
9 = Power cal Checksum error
A = FPGA main chain load fail
B = Turbo FPGA load fail
C = Modem card FPGA load
D = MUX FPGA load
E = Demux FPGA load
F = No PLL lock (Hi-Stab Ref) – suppresses TX
b = Tx Traffic status
0 = Tx traffic OK
1 = No clock from terrestrial interface
2 = Tx FIFO slip
3 = AIS detected on incoming data
4 = AUPC upper limit reached
5 = Ref activity fault