background image

CRS-280L L-Band IF Switch for 1:N Redundancy

Revision 1

Appendix B

MN/CRS280L.IOM

B–2

B.2

Power Supply Module Removal Procedure

Step

Task

1


DISCONNECT THE CRS-280L FROM ITS
POWER SOURCE!


For AC Units (pictured):
Shut off the AC power
switch on both power supply modules and
disconnect both power cords from their receptacles.

For DC Units: Make sure to disconnect both power
cords from their DC power sources, then unscrew the
positive, negative, and ground leads from the
terminal block of the module being replaced.

2

Loosen the four captive mounting screws of the
module to be replaced, then carefully pull the module
plate away from the unit.