2 power / ground connections, 1 alternating current (ac) power connectors, 2 direct current (dc) power connectors (optional) – Comtech EF Data CRS-280L User Manual
Page 37: 3 ground connector

CRS-280L L-Band IF Switch for 1:N Redundancy
Revision 1
Connector Pinouts
MN/CRS280L.IOM
3–5
3.3.2 Power / Ground Connections
3.3.2.1 Alternating Current (AC) Power Connectors
Two AC power supplies – one primary, one backup – are provided. For each, a
standard, detachable, non-locking 3-prong power cord (IEC plug) supplies the
Alternating Current (AC) power to the CRS-280L. Observe the following:
3.3.2.2 Direct Current (DC) Power Connectors (optional)
Two DC power supplies – one primary, one backup – are
optionally available. For each, a standard, 3-screw terminal block
with fuse holder supplies the Direct Current (DC) power to the
CRS-280L. Observe the following:
3.3.2.3 Ground Connector
A #10-32 stud, located to the lower left hand side of the CRS-280L rear panel, is
provided for connecting a common chassis ground among equipment.
Note: The AC power connector provides the safety ground.
IMPORTANT
For continued operator safety, always replace fuses with the correct type and
rating.
Standard AC Power Specifications
Input Power
25W typical
Input Voltage
100 - 240 volts AC, +6%/-10% - autosensing
(total absolute max. range is 90-264 volts AC)
Connector Type
IEC
Fuse Protection
1.0A Slow-blow (115 volt AC operation)
2.0A Slow-blow (230 volt AC operation)
Line and neutral fusing
20 mm type fuses
Optional DC Power Specifications
Input Power
25W maximum
Input Voltage
36 to 72 VDC; 6.25 amps
Connector Type
Terminal Block
Fuse Protection
6.25A Slow-blow