CRS-280L L-Band IF Switch for 1:N Redundancy

Revision 1

Redundancy System Configuration / Operation

MN/CRS280L.IOM

5–2

5.3

1:N Redundancy System Power-up Sequence

After the 1:N redundant system cabling is complete, and the companion switch and modems have
been initially configured, the complete sysyem may be powered up. The typical equipment power-
up sequence is as follows:

Step

Instructions

1

Turn on the redundant and traffic L-Band modems.

2

Power up the CRS-280L L-Band IF Switch switch by turning both power supply
switches, located on the CRS-280L rear panel, to the

on position.

Once the power supplies are turned on, both power status LEDs (A and B) on the
front panel should illuminate green.

3

Power up the companion switch as applicable (e.g., turn on the system controller /
data switch for the CRS-300, CRS-400, or SMS-7000; turn on the CRS-500 Control
Switch Unit (CSU), etc.)

IMPORTANT

The CRS-280L is designed to operate with only one power supply energized.
However, it is recommended to continually operate the system with both
supplies energized for redundancy.

5.3.1 CRS-280L operations with the CRS-500 M:N Redundancy System

While the CRS-500 M:N Redundancy System supports 2:N redundancy and IP Sub-MUX
operation, the CRS-280L L-Band IF Switch is limited to 1:10 (maximum) redundancy – 2:N
redundancy and IP Sub-MUX operation are not supported
by the CRS-280L.