beautypg.com

1 overview, 2 crs-280l input power cord connections – Comtech EF Data CRS-280L User Manual

Page 49

background image

5–1

Chapter 5. REDUNDANCY SYSTEM

CONFIGURATION / OPERATION

5.1

Overview

IMPORTANT

In order to avoid damage to the modems, the companion redundant switch, and
the CRS-280L L-Band IF Switch, and it is important for the user to follow this
sequence of configuration:

First, connect cables between the (powered OFF) modems, companion
redundancy switch, and CRS-280L as outlined previously in
Chapter 4.
CABLES AND CONNECTIONS.

Second, configure the modems for 1:N redundant operation, as outlined in
the respective modem and companion switch
Installation and Operation
Manuals.

Third, once the modems have been properly configured for 1:N redundant
operations, the user should follow the instructions in the next two chapter
sections in the sequence they are presented.

5.2

CRS-280L Input Power Cord Connections

IMPORTANT

Do not turn the CRS-280L power supply switches to the

on position until all

system connections are in place.

Connect the AC power cords as follows:

Step

Instructions

1

Ensure that both power supply switches are in the

off position before connecting

the power supply power cords.

2

Each CRS-280L is supplied with two power cords – one for each power supply
power input. Connect the female end of each supplied power cords to its mating
socket.

3

Plug both power cords into the AC power source.