Belshaw Adamatic Mark II-Gas Donut Robot User Manual
Page 57
![background image](https://www.manualsdir.com/files/775228/content/doc057.png)
Belshaw Bros., Inc.
• www.belshaw.com • Phone 206-322-5474 • Fax 206-322-5425
Donut Robot Mark II-Gas TS
MN-1018EN
17
THE PILOT WILL NOT IGNITE, BUT THE CONVEYOR RUNS.
Possible Causes
What To Do
The gas is not turned on or the connection to gas
source is loose.
Turn on gas. Reconnect to gas source.
The high temperature limit control switch has
been tripped.
Push the red reset button on the back of the control
box.
The thermostat has been calibrated incorrectly.
Recalibrate the thermostat.
WARNING
To avoid being burned, electrocuted, or otherwise
injured, before doing any of the following, turn
off the machine, allow the shortening to cool, and
disconnect the machine from the power source.
The high temperature limit control is defective.
Replace the high temperature limit control.
The thermostat is defective.
Replace the thermostat.
THE GAS SYSTEM HEATS, BUT THE CONVEYOR WILL NOT RUN.
Possible Causes
What To Do
The input voltage is incorrect.
Supply the correct power as specified on the data
plate.
WARNING
To avoid being burned, electrocuted, or otherwise
injured, before doing any of the following, turn
off the machine, allow the shortening to cool, and
disconnect the machine from the power source.
There is a short circuit.
Find it and repair it.
The wiring harness in the conveyor drive
assembly is not connected.
Check the connection of the pin connector from the
conveyor drive assembly to the socket connector in
the heater head enclosure. Make sure the pins in the
pin housing are securely seated in the housing.
The conveyor drive power switch is defective.
Replace the switch.
The nylon brake dog is binding on the conveyor
brake motor.
If the brake dog is worn, replace it. If it is too tight,
loosen it. If the spring is weak or missing, replace it.
The brake motor is defective.
Replace the brake motor.
An internal wire is interfering with the nylon
brake dog.
Move the wire.
THE GAS SYSTEM HEATS, BUT THE CONVEYOR WILL NOT RUN