Cleaning – Belshaw Adamatic Mark II-Gas Donut Robot User Manual
Page 30
![background image](https://www.manualsdir.com/files/775228/content/doc030.png)
Belshaw Bros., Inc. www.belshaw.com
• Phone 206-322-5474 • Fax 206-322-5425
24
MN-1017EN
Donut Robot Mark II-Gas OM
WARNING
If you allow shortening to overflow the
container, the shortening could burn you,
and it will get on the floor, possibly causing
slips, falls, injury, or even death. If
shortening does get on the floor, thoroughly
clean and dry the floor right away.
3. When the shortening stops flowing, tilt up
the side of the kettle opposite the siphon.
Place a wedge under the side of the kettle to
hold it up. The remaining shortening will
now flow toward the siphon.
4. Set aside the container of shortening.
5. Remove the filter assembly.
6. Place a different container under the valve
assembly and start the siphon again. Drain
the remaining shortening and discard it; it
will be full of sediment.
Cleaning
1. Remove the siphon from the Donut Robot.
2. Squeeze the bulb several times to expel
shortening from the siphon.
3. Wipe the siphon clean and hang it with the
bulb side up so any remaining shortening
will drain. Place a pan under the siphon to
collect the shortening.
4. Rinse the filter bag and hang it to dry. You
may launder it as needed.
WARNING
After washing, be sure the Filter Flo
Siphon is completely dry before using it
again. Moisture will cause hot shortening
to spatter, which may cause serious injury.