1 installation, Unpacking the fryer, Conforming to codes – Belshaw Adamatic Mark II-Gas Donut Robot User Manual
Page 41

Belshaw Bros., Inc.
• www.belshaw.com • Phone 206-322-5474 • Fax 206-322-5425
Donut Robot Mark II-Gas TS
MN-1018EN
1
1 Installation
Unpacking the Fryer
Before you unpack and install the fryer, you
should first select a workstation. The work
station should allow at least 2”/5 cm clearance
between the machine and all construction,
whether combustible or noncombustible. To
provide for proper operation and servicing, you
should allow 2 ft/0.6 m clearance at the outfeed
end of the fryer.
In a prominent location, post instructions to be
followed in the event the user smells gas. Obtain
this information by consulting your local gas
supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors or liquids in the vicinity
of this or any other appliance.
WARNING
Improper installation, adjustment,
alteration, service or maintenance can
cause property damage, injury or death.
Read the installation, operating and
maintenance instructions thoroughly
before installing or servicing this
equipment.
Conforming to Codes
The installation of this fryer must conform with
local codes, or in the absence of local codes, with
the National Fuel Gas Code (ANSI Z223.1-
1988), with the Natural Gas Installation Code
(CAN/CGA-B149.1), or with the Propane
Installation Code (CAN/CGA-B149.2),
including:
• The fryer and its individual shutoff valve
must be disconnected from the gas
supply piping system during any
pressure testing of that system at test
pressures in excess of 1/2 psig (3.45
kPa).
• The fryer must be isolated from the gas
supply piping system by closing its
individual manual shutoff valve during
any pressure testing of the gas supply
piping system at test pressures equal to
or less than 1/2 psig (3.45 kPa).
The fryer, when installed, must be electrically
grounded in accordance with local codes, or in
the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70, or with the
Canadian Electrical Code, CSA C22.1, as
applicable.
WARNING
Electrical Grounding Instructions
This appliance is equipped with a three-
prong (grounding) plug for your protection
against shock hazard and should be
plugged directly into a properly grounded
three-prong receptacle. Do not cut or
remove the grounding prong from this
plug.