C.2
Location requirements
C.2.1 Floor quality
The floor of the room where the machine is to be installed must have a
sufficient surface strength. The location of the machine must be free of
vibrations.
If several machines are to be installed in one room, the static load bea-
ring capacity of the ceiling must be considered.
Weight:
Machine with accessories approx 120 kg
C.2.2 Interior climate
Climatic requirements for the operating room:
The machine must only be stored or operated in closed operating
rooms.
Room temperature
+10° C to +45° C
Relative humidity
max. 80 %
C.2.3 Floor space requirements
For operation during production and for service works, the machine
must be freely accessible from all sides. On all sides, there must be a
minimum clearance of 1 m.
Dimensions:
L x W x H
2300 x 1500 x 1700 mm
NOTE - Electromagnetic interference
The machine must not be installed in the immediate vicini-
ty of devices or electrical components (e.g. transformers)
generating a strong magnetic field as otherwise the cor-
rect function of the program control may be impaired.