beautypg.com

Operation – Beisler 1265-4 User Manual

Page 32

background image

Operating Instructions Automatic Single-Head Serging Machine 1265-4

Beisler GmbH

B-22

B.3

Operation

B.3.6 Resetting the day counter to zero

This function is used to reset the day counter to zero before a new production

cycle or after a completed cycle.

1. Move to access level 2:

• Press the a key.

j

2. Select the function for resetting the day counter:

F

• Keep the g key depressed for approx 3 seconds.

The day counter is reset to zero.

3. Confirm reset and return to access level 1:

• Press the ( key.

Display:

S

= 0000

B.3.7 Activating manual sewing

If the function Manual sewing is enabled, the photocell is deactivated and

the footswitch is activated.

1. Enable the function:

• Press the b key.

T

2. Control sewing speed by depressing footswitch pedal.

3. Disable the function:

• Press the b key.

T

The photocell is activated, the footswitch is deactivated.

NOTE - Pocket pouch

This function can be used for serging pocket pouches. To start

automatic sewing after manual sewing, depress the short por-