beautypg.com

Adjustment peripherial board, Manual rewind option – Avery Dennison Rewinder User Manual

Page 27

background image

Manual Rewind Option

06/01

Rev. 2.09

27

Adjustment peripherial board

30 mA

Z0131.cdr

P1

CN 5 touch down
home sensor

Poti R 41 label present sensor

CN 3 infrared sensor

JP 2 signal / power
connecting to dispenser

Additional
information – this
board can be used
for:
- applicator

option

- cutter

option

- rewinder

option

- infeed

option

- cutter / stacker

option

CN 6 test point

CN 4 main stepper connector

Depending on the mounted option – this sensor is used in
different ways :
-

cutter / stacker no adjustment necessary

-

cutter no adjustment necessary

-

infeed use Poti P1 to adjust the sensor

-

rewinder set current to 30 mA by use of P1 with
unplugged sensor as illustrated.

- for

label present sensor (manual application) use

Poti R 41 to adjust between test point CN 6 and
ground a value of 2.5 Volt (no media in and cover
closed)

Poti P 1 infrared sensor

CN5 signals :

touch down – digital signal
that the applicator base
plate get in contact with the
surface of He product !
Applicator moves back.

Peripherial board 99054