Manual Rewind Option

06/01

Rev. 2.09

23

Fig. 4: Setting the peripheral board: disconnect the sensor, set the current by

means of P1 to 30 mA.

If the difference is big enough the sensor itself has to be adjusted now.

1. Select SYSP.

2. Select PEPH.

3. Select RWND.

4. Select RADJ (behind DIRL and DIRR) and select YES by using ENTER or leave the menu

by using ESC.

5. First adjust the home position of the dancer - RNUL. Acknowledge with ENTER – shown

is the momentary sensor value, by moving the dancer, the value is changing. By pressing
ENTER the value is overtaken by the program.

Attention: Do not set the value at the limit position but the position ~ 5 mm before!

6. Acknowledge the value by pressing ENTER. The display switches to REND.

7. Acknowledge by pressing ENTER – move the dancer arm to the opposite position (close

to the support foot, shown is the actual value of the sensor. Accept as well by pressing
ENTER – the value will be accepted.

Attention: Do not set the value at the limit position but the position ~ 5 mm before!

Watch carefully that the difference between the two shown values is bigger the
100 !

Is the program step broken by using the ESC key the printer is using default
values – maybe ending with mail functions.

30 mA

Z0131.cdr

P1