background image

GreenStart Igniter 2 for Freestanding Stoves

Installation Instructions

(SKU 94400953)

Page 3 of 27

17601769.docx— 12/11/13

© Travis Industries, Inc.

All Stove Models – Igniter Hose Clamp

A hose clamp is attached to each igniter hose. You will need to set the clamp while attaching the hose to
the igniter. See the photos below.

Using a Room Blower Outlet with the GreenStart 2 Igniter

An extra outlet (sku 94400953) for the room blower is included with the GreenStart Igniter 2 for
Freestanding Stoves. To access this outlet remove the top of the pump box using a 5/16” nutdriver.

There are two ways to route the cord into the pump box:

a. Route the cord and

cord restraint through
the right side of the
pump box using the
“U” shaped cutout
above the igniter hose.

b. Route the cord through

the bottom of the
pump box and secure
in place with the
included cord restraint
as shown below.

Replace the pump box top after plugging in the cord.