Features and Specifications

Travis Industries

4140312

100-01305

Installation Options

 Residential or Mobile Home
 Straight or Corner Placement
 Flush or Recessed Face


 Raised or Floor Placement
 Internal

or

External Chase

 Horizontal or Vertical Vent
 Bedroom

Approved

Heating Specifications

Natural Gas

Propane

Approximate Heating Capacity (in square feet)*

Up to 650

Up to 650

Maximum BTU Input Per Hour

16,500

16,500

*

Heating capacity will vary with floor plan, insulation, and outside temperature.

Dimensions

35-7/8"

8" External Diameter

13-1/2"*

45°

20-1/8"

NOTE: 1/2" clearance is
required to the angled
sides and rear of the
fireplace.

See "Gas Line

Requirements" for

Details on the Gas Inlet

7-1/4"

4-7/8"

Nailing Brackets

4"

Nailing

Bracket

(Framing)

27-1/4"

Rear Vent Configuration

8-1/2"

12-3/4"*

Top Vent Configuration

Lifting Bracket (may

be bent down)

34-1/8"

* Includes the required 1/2" clearance.

* Includes the required 1/2" clearance.