24 Installation

(for qualified installers only)

Travis Industries

4140312

100-01305

Approved Vent Configurations

Restrictor Position

 An exhaust restrictor and diffuser are built into the appliance to adjust the flow rate of intake air and

exhaust gases. Depending upon the vent configuration, you may be required to adjust the restrictor
and/or diffuser. The charts for acceptable vent configurations detail the correct vent restrictor and
diffuser positions.

Exhaust Restrictor Adjustment

If the diffuser is required to be in position # 2, you may wish to adjust the diffuser while the exhaust

restrictor is removed.

To Access the Restrictor:

Remove the face (with the stove
cool).

1

2

Determine the correct restrictor position (see the charts under "Approved

Vent Configurations" - the factory position is #1).
Lift up the adjustment plate and move it so the correct notch falls into the

slot on the adjustment bracket.

This restrictor is in position 1

(factory setting).

Adjustment Bracket

Adjustment

Plate

To adjust, lift the adjustment plate and

pull it forward

Restrictor Position

# 7

# 6

etc...

# 2

This restrictor is in position 3.

To Adjust the Restrictor: