Travis Industries
4140312
100-01305
Diffuser Plate Adjustment
Certain vent configurations require the diffuser plate to be adjusted (refer to the approved vent
configuration charts for details). Position # 1 is stock (flat). Position # 2 is bent. See the directions below
to change the diffuser to position #2.
If the diffuser is required to be in position # 2, you may wish to adjust the diffuser while converting the
appliance to rear-vent configuration.
NOTE: To better
access the diffuser,
you may wish to move
the restrictor to the # 1
postion.
Remove the diffuser.
Secure the diffuser plate
with the screws
removed earlier.
Bend the round portion of the
diffuser 90°.
Before (Stock - Position # 1)
After (Position # 2)
DIFFUSER SIDE VIEW
Back Wall of Firebox