16 installation – Avalon Firestyles Bed & Breakfast Installation User Manual
Page 16

16 Installation
(for qualified installers only)
Travis Industries
4140312
100-01305
Minimum Framing Dimensions - Rear Vent Configuration
NOTE: Looking Glass & Wilmington Faces require a raised fireplace – see Face Dimensions on page 32 for details.
Route the electrical line to a position
to the right rear of the fireplace.
27-1/4"
Vent Clearances:
1" to the sides, 1" below, and 3" above
the vent to combustibles.
20-1/4"
34-1/4"
12-3/4"
Firestop
(required)
HINT: we recommend
reinforcing the upper corners of
the fireplace opening.
NOTE: The rear vent may require extra
clearance - make sure to accommodate the
vent when determining the framing.
Center of Rear Vent
WARNING: A cut-out for the gas line
may be required on the framing.
Thermostat or Remote
Control Wire (right side)
34-1/4" Minimum
Enclosure Height
6"
5"
1"