16 Installation

(for qualified installers only)

Travis Industries

4140312

100-01305

Minimum Framing Dimensions - Rear Vent Configuration

NOTE: Looking Glass & Wilmington Faces require a raised fireplace – see Face Dimensions on page 32 for details.

Route the electrical line to a position

to the right rear of the fireplace.

27-1/4"

Vent Clearances:

1" to the sides, 1" below, and 3" above

the vent to combustibles.

20-1/4"

34-1/4"

12-3/4"

Firestop

(required)

HINT: we recommend

reinforcing the upper corners of

the fireplace opening.

NOTE: The rear vent may require extra

clearance - make sure to accommodate the

vent when determining the framing.

Center of Rear Vent

WARNING: A cut-out for the gas line

may be required on the framing.

Thermostat or Remote

Control Wire (right side)

34-1/4" Minimum

Enclosure Height

6"

5"

1"