beautypg.com

Installation – Avalon Firestyles Bed & Breakfast Installation User Manual

Page 23

background image

Installation

(for qualified installers only)

23

Travis Industries

4140312

100-01305

Approved Vent

 Rear vent configurations use 8" diameter Simpson Dura-Vent Model Direct-Vent Pro (or GS)*.
 Top vent configurations use 8" or 6-5/8" diameter Simpson Dura-Vent Direct-Vent Pro (or GS)*. If

using 6-5/8" diameter vent, attach the 8" to 6-5/8" reducer (Travis part # 98900165) to the fireplace.

* Other vent may be approved with this fireplace. Check with the vent manufacturer for details.

 Always use the high-wind cap (or high-wind sconce cap, part # 58DVA-HSCH or 46DVA-HSCH).
 Installation instructions for Simpson Dura-Vent may be found at www.duravent.com.

Vent Installation

 Slide the vent sections together and turn 1/4 turn until the sections lock in

place.

 Screws are not required to secure the vent. However, three screws may be

used to secure vent sections together if desired.

 High temperature sealant is recommended at the appliance starter section

connection (use high-temperature silicone or Mill-Pac®).

 If disassembly is required, at time of re-assembly check to see if the vent

creates a tight fit. If it does not, apply high temperature sealant to the joints
of the affected sections.

 Horizontal sections require a 1/4" rise every 12" of travel.
 Horizontal sections require non-combustible support every three feet (e.g.: plumbing tape).

6-5/8" Diameter Vent

(minimum 12" vertical rise)

Reducer - # 98900165

This manual is related to the following products: