Installation, Rear vent configuration with vertical termination, For qualified installers only) – Avalon Firestyles Bed & Breakfast Installation User Manual
Page 29

Installation
(for qualified installers only)
29
Travis Industries
4140312
100-01305
Rear Vent Configuration with Vertical Termination
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and
diffuser positions.
Up to four elbows (45° or 90°) may be used.
Use 8" diameter vent.
Only one horizontal elbow may be used.
Restrictor Position # 3
Diffuser Position # 1 (stock)
5 feet
10 feet
15 feet
20 feet
25 feet
30 feet
0 feet
40' (max)
5 feet
10 feet
0 feet
5 feet
10 feet
14' (max)
15 feet
20 feet
25 feet
30 feet
0 feet
0 feet
NOTE:
Horizontal sections require a
1/4" rise every 12" of travel.
10 feet
40' (max)
14' (max)
NOTE:
Restrictor positions are
based upon lab tests.
The ideal restrictor
position may vary
slightly, especially when
the termination is near a
demarkation line.
5 feet
NOTE:
One 45° or 90° elbow may
be used between horizontal
sections. Horizontal length
is caculated by adding each
horizontal run together.
35 feet
35 feet
6' (min)
6' (min)
NOTE:
Two 45° elbows
may be used.
Restrictor Position # 1 (stock)
Diffuser Position # 1 (stock)
Restrictor Position # 2
Diffuser Position # 1 (stock)
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
This is considered a
vertical elbow
Horizontal length is calculated by adding
both lengths of horizontal run
(Horizontal Length = H1 + H2).
H1
H2