beautypg.com

Finalizing the installation, For qualified installers only), Air shutter adjustment – Avalon Firestyles Bed & Breakfast Installation User Manual

Page 39: Special instructions for concealment cover

background image

Finalizing the Installation

(for qualified installers only)

39

Travis Industries

4140312

100-01305

5. Install the logs (see page 42).
6. Replace the glass.
7. Start the heater.
8. Leak test all gas joints.
9. Check the air shutter following the directions below.

Air Shutter Adjustment

Let the heater burn for fifteen minutes (make sure the logs and glass are in place). The flames should be
yellow with no sooting. Adjust the air shutter, if necessary, to achieve the correct looking flame.

10. Turn the flame adjust knob to its highest position - the flames should not contact the top of the firebox. Check

the flame on low position. The flames should burn off of each burner hole. If the heater does not work
correctly, contact your Travis dealer for a remedy.

Special Instructions for Concealment Cover

11. Give this manual to the home owner for future reference and fully explain operation of this heater. For

comprehensive operating and maintenance instructions, refer to the Owner's Manual (part # 100-01305).

ACID WASH WARNING: Before installing the faceplate, make sure any masonry that has been treated with acid
wash has been properly neutralized (this is used primarily with brick faces). Acid wash (muriatic acid) is used to
remove excess mortar. If not properly neutralized with an ammonia solution, the plated face may develop a
permanent tarnish when the acid evaporates over time. Contact your dealer if uncertain your facing has been
properly neutralized.

NOTE: If the air shutter is all the way

open, yet the flames remain sooty, shut

off gas to the fireplace and contact a

qualified gas service technician.

Correct

Flames should be blue at the

base, yellow-orange on the top.

If the flames are too tall or sooty on the

ends, open the air shutter.

Not Enough Air

If the flames are all blue and

short, close the air shutter.

Too Much Air

NOTE: The logs must be installed correctly to

monitor the flame while adjusting the air shutter.

Moving the air shutter control to the right

gives the flame less air (closed) - making it

more orange. Moving it to the left gives the

flame more air (open), making it more blue.

For fine adjustments use a screwdriver to

tap the air shutter.

ADJUSTING THE AIR SHUTTER

Less Air

More Air

Phillips
Screwdriver

Air Shutter

Control

Certain faces have

nametags that

interfere with the

concealment cover.

For these faces,

remove the knock-

out and file down any

shart edges.

Certain faces may

contact the

concealment cover

when it is open.

Place the two felt

tabs (included in

owner's pack) on the

concealment cover

to prevent

scratching.

FELT TAB INSTALLATION

CONCEALMENT COVER KNOCK-OUT PLATE

This manual is related to the following products: