Installation
(for qualified installers only)
15
Travis Industries
4140312
100-01305
Minimum Framing Dimensions - Top Vent Configuration
NOTE: Looking Glass & Wilmington Faces require a raised fireplace – see Face Dimensions on page 32 for details.
Route the electrical line to a position
to the right rear of the fireplace.
Thermostat or Remote
Control Wire (right side)
If using an elbow directly off the
fireplace, the vent will be centered
41.75" above the base of the
fireplace.
The fireplace enclosure must
be a minimum 48.75" above
the base of the fireplace.
NOTE: Do not build into the
area above the fireplace
(except for the required
framing members).
20.25"
48.75" Min.
14"
Firestop
(required)
HINT: We recommend
installing the shaded
framing after the fireplace
is in place.
WARNING: A cut-out for the gas line may be
required on the framing.
HINT: we recommend reinforcing the
upper corners of the fireplace opening.
6"
5"
1"
Vent Clearances:
1" to the sides, 1" below, and 3" above
the vent to combustibles.
34.25"