Hardware Preparation and Installation

COMX-P40x0 ENP2 Installation and Use (6806800R95B)

29

Power Requirements

This board is designed to operate with the input voltages and currents as defined in the
following tables.

2.2

Unpacking and Inspecting the Enclosure

Read all notices and cautions prior to unpacking the product.

Table 2-3 Current Drawn

State

12v

VCC_RTC

Idle

2.81A

100 uA

Full Loading (Linux)

2.91A

100 uA

Table 2-4 COMX-P4080-4G-E-ENP2

Volts

Amps

Power

12

2.6

31.2

Total Power dissipation (W)

31.2

Damage of Circuits

Electrostatic discharge and incorrect installation/removal of the product can damage
circuits or shorten their life.

Before touching the product make sure that you are working in an ESD-safe
environment with protective equipment such an ESD wrist strap and ESD shoes. Hold
the product by its edges and do not touch any components or circuits.