U-Boot provides "rcw" utilities to switch SerDes lanes among the twelve SerDes/RCW options.
A checking feature is also supported. Below is a usage sample of the utilities.

The steps below are used to activate specific SerDes/RCW options.

Run "rcw active " to activate the SerDes/RCW option#.

Power off the board.

For RCW options #7 or #8, a means to change the SERDES clock settings must be provided
by the customer's carrier board.

Power up the board.

rcw list

-

Lists the status of RCW sections

rcw active

-

active RCW. range [1..12]

rcw check current

-

Checks the current RCW with which system boots up

rcw check active

-

Checks the status of the active RCW section

rcw check backup
[option#]

-

Checks the status of all or # backup RCW section(s).