beautypg.com

Hardware preparation and installation, 1 environmental and power requirements, 1 environmental requirements – Artesyn COMX-P40x0 ENP2 Installation and Use (August 2014) User Manual

Page 27: Table 2-1, Environmental requirements, Chapter 2

background image

Chapter 2

COMX-P40x0 ENP2 Installation and Use (6806800R95B)

27

Hardware Preparation and Installation

2.1

Environmental and Power Requirements

2.1.1

Environmental Requirements

The following module environmental requirements must not be exceeded.

The following table provides the environmental requirements for the module.

Thermal Requirements

A standard passive heat sink can be provided by Artesyn; 12 CFM system airflow volume (at
71

o

C) is needed for the heat sink to keep sufficient cooling to the module. Contact your

Artesyn sales representative for detailed thermal information.

Operating temperature refers to the temperature of the air circulating around the module
and not the component temperature.

Table 2-1 Environmental Requirements

Requirement

Operating

Non-Operating

Temperature

-40°C to +71°C

-50°C to +100°C

Humidity

to 100% RH

to 100

% RH

Vibration Sine (10mins/axis)

5G, 15 to 2000Hz

Vibration Random (1hr/axis)

0.04g2/Hz, 15 to 2000Hz
(8GRMS)

Shock

30g/11mS(half sine)

Altitude

-60 to 4000 m ASL