Analog Way PULSE LE - Ref. PLS200 Programmer's Guide User Manual
Page 40
40
Group
Name
CmdResp Description
Read
/
Write
Min
Value
Max
value
Default
value
Values
Index #1
Index #2
PE_CLOSING_DURATION
cD cD
Layer closing transition
duration
Rd/Wr0
255 10
Unit = 1/10s
0 = Current
preset
1 = Next preset
2 = Previous
preset
3 = Memory
Preset 1
4 = Memory
Preset 2
5 = Memory
Preset 3
6 = Memory
Preset 4
2 =
Background
Layer for
output 1
3 = Pip 1 Layer
for output1
Background
Layer for
output 2 in
matrix mode
8 = Audio
Output 1
9 = Audio
Output 2
PRESET
CONTROL
TAKE
TK TK
TAKE, Next preset becomes
Current
Rd/Wr0
1
0
TAKEAVA
TA TA
Available TAKE flag
Rd
0
1
1
TAKEINFO
TI
TI
TAKE information
Rd
0
2
0
0 = 1 shot TAKE
1 = 2 shot TAKE
2 = Sequenced TAKE
TBAR
NT NT TBAR value
Rd/Wr0
100000
Unit = 0,01%
COPY_FROM
Nf
Nf
Source for preset copy
Rd/Wr0
6
0
0 = Current preset
1 = Next preset
2 = Previous preset
3 = Memory Preset 1
4 = Memory Preset 2
5 = Memory Preset 3
6 = Memory Preset 4
COPY_TO
Nt
Nt
Destination for preset copy
Rd/Wr0
6
0
0 = Current preset
1 = Next preset
2 = Previous preset
3 = Memory Preset 1
4 = Memory Preset 2
5 = Memory Preset 3
6 = Memory Preset 4
COPY_CTRL
Nc Nc
Preset copy control
Rd/Wr0
1
0
Auto reset