Analog Way DI-VENTIX II - Ref. DVX8044 Programmer's Guide User Manual
Page 34

34
TBAR
NT NT
tbar value
Rd/Wr 0
1000
0
in 1/100 of %
TBAR_POS_STATUS
NK NK
tbar position status
Rd
0
1000
0
in 1/100 of %
TBAR_OFFSET_LOW
NL NL
tbar bottom offset
Rd/Wr 0
1000
100
in 1/100 of %
TBAR_OFFSET_HIGH
NH NH
tbar top offset
Rd/Wr 0
1000
900
in 1/100 of %
TBAR_STATUS
NS NS
tbar status
Rd/Wr 0
3
0
0 = Tbar not allowed
1 = Tbar allowed
2 = Tbar ready
3 = Tbar active
TBAR_ABORT
ND ND
cancel any tbar operation
started (clear tbar
position status)
Rd/Wr 0
1
0
(auto clear)
CLIGN_PRESET
NP NP
selected preset
Rd/Wr 0
2
2
0 = Current Preset
1 = Next Preset
2 = Previous Preset
CLIGN_LAYER
NC NC
selected layer
Rd/Wr 0
7
0
0 = Background Frame
1 = Layer A
2 = Layer B
3 = Layer C
4 = Layer D
5 = Logo A
6 = Logo B
7 = Frame Mask
CLIGN_ENABLE
NE NE
blinking enable
Rd/Wr 0
1
0
COPY_FROM
Nf
Nf
source for preset copy
Rd/Wr 0
6
0
0 = Current Preset
1 = Next Preset
2 = Previous Preset
3 = Memorized Preset 1
4 = Memorized Preset 2
5 = Memorized Preset 3
6 = Memorized Preset 4
COPY_TO
Nt
Nt
destination for preset
copy
Rd/Wr 0
6
1
0 = Current Preset
1 = Next Preset
2 = Previous Preset
3 = Memorized Preset 1
4 = Memorized Preset 2
5 = Memorized Preset 3
6 = Memorized Preset 4
COPY_CTRL
Nc
Nc
preset copy control
Rd/Wr 0
1
0
(auto clear)