A3: Examples
Document notation:
1) Command without index : SWITCHER_MODE
Command to set the switcher mode to mixer mode: 0CM
Answer: CM0
2) Command with 1 index : OFORMAT
Command to set the Main output format to XGA: 0,12OF
Answer: OF0,12
3) Command with 2 indexes : PE_INPUTNUM
Command to set the input 4 displayed in Layer A of Next Preset: 1,1,4IN
Answer: IN1,1,4
4) Read command without index : TAKEAVA
Read command to know if the TAKE command is available: TA
Answer: TA1
5) Read command with 2 indexes : SET_ASPECT_RATIO_OUT
Read command to know how is displayed a DVI signal plugged on the input 4: 3,1,sB
Answer: sB3,1,2
A4: Error codes
Answer : E10
Answer : E11
Answer : E12
Some commands are only available as [Read command], they are status and are colored in blue as this line.
Some commands are colored in yellow as this line to indicate they were added or modified in this version.