Save -23 – AMETEK SGI Series User Manual
Page 75

Sorensen SGI Series
Calibration and Verification
M550221-01 Rev AA
3-23
or by entering the value with "Keypad 0-9". For more details see
Section 3.6.
P
ROGRAMMING
C
URRENT
Go directly to Current programming by pressing the current key.
The Default Programming menu is displayed and the Editing Arrow is to
the right of the "Set Curr" editable value. Edit the value by NavPad
up/down or by entering the value with "Keypad 0-9". For more details see
Section 3.6.
P
ROGRAMMING
O
VERVOLTAGE
P
ROTECTION
Go directly to Overvoltage trip point programming by pressing the
overvoltage key. The Default Programming menu is displayed and the
Editing Arrow is to the right of the "Set OVP" editable value. Edit the
value by NavPad up/down or entering the value with "Keypad 0-9". For
more details see Section 3.6.
3.8.2 Save
There are 11
memory locations (PwrOn, 1 through 9, LAST 0/1) into which a
programmed output configuration of Voltage, Current, OVP (Overvoltage
Protection trip point) and Output Condition can be stored. The LAST 0/1
configuration stores and recovers programmed Voltage, Current, OVP
(Overvoltage Protection trip point), Output Condition, and Foldback Protection
when power supply is turned off.
From Home Menu Page 1 press (F1) to enter
the Save menu. Voltage, Current and OVP values programmed in the Default
Programming menu will be pulled into the Save menu, top line, upon reaching
that menu. In addition, the present output condition, output engaged or output
disabled, will be indicated.
E
DIT
V
OLTAGE
,
C
URRENT AND
OVP
Toggle between the editable items using the NavPad and edit Voltage,
Current and OVP to appropriate values (see Section 3.6 for editing
details).
Values pulled in from Default
Programming Menu.
Save to location.
Values currently saved
in location.