The PID Tab
The PID tab is used to specify PID settings for programming.
Image reduced for clarity
Controls
Control
Function
Options
API Command
PID
Paradigm
this control allows for preset PID values to be automatically loaded.
Once a selection is made from the drop-down menu, all values will
populate based on the PID configuration chosen.
Adtec
Tandberg
ATSC PGM 3
ATSC PGM 4
ATSC PGM 5
ATSC PGM 6
ATSC PGM 7
ATSC PGM 8
ATSC PGM 9
WBU-ISOG
none-GUI only
PMT
identifies packets with the Program Map Table. Program Map Tables
are used to describe the properties of a single program.
user-defined
hexadecimal
*.ECMD PPI
TS ID
Transport Stream identifier; used in the PAT packet to identify one
stream from others within the multiplex.
user-defined
hexadecimal
*.ECMD TSI
Video
identifies packets which contain video Packetized Elementary Stream
(PES) data.
user-defined
hexadecimal
*.ECMD VPI
PCR
identifies packets which contain the Program Clock Reference (PCR;
"Master Clock") adaptation field
user-defined
hexadecimal
*.ECMD PRP
Audio 1
identifies packets which contain audio content for Channels 1 and 2
user-defined
hexadecimal
*.ECMD API 0
Audio 2
identifies packets which contain audio content for Channels 3 and 4
user-defined
hexadecimal
*.ECMD API 1
Audio 3
identifies packets which contain audio content for Channels 5 and 6
user-defined
hexadecimal
*.ECMD API 2
Audio 4
identifies packets which contain audio content for Channels 7 and 8
user-defined
hexadecimal
*.ECMD API 3