VEC-4001K Owner’s Manual
Professional Function Generator
27
THEORY OF OPERATION AND SPECIFICATIONS
Your generator kit is built around the MAX038CPP, a special-function IC at U1
which provides sinewave, squarewave, and triangle-wave output over a wide
frequency range. Op-amp U2 buffers the generator IC's output signal and
establishes adjustable DC Offset. U3 buffers the IC's VCO reference voltage to
ensure stability. Q1/Q2 provide low-Z output with short-circuit protection. All
source voltages are regulated (U4-U7).
Typical Specifications:
Power Requirements:.......................12 VAC
Frequency Range:............................1 Hz to 1 MHz in six decade ranges
Amplitude Range:............................0 to 12 volts peak-to-peak
DC Offset Range: ............................-6 volts to +6 volts
Output Impedance: ..........................400 ohms, short-circuit protected
- SWR-66 (5 pages)
- SWR-584C (28 pages)
- AT-100 (5 pages)
- SWR-584B (25 pages)
- VEC-1856 (9 pages)
- VEC-1862 (9 pages)
- DL-2500 (2 pages)
- VEC-896 (17 pages)
- VEC-820K (20 pages)
- VEC-821K (22 pages)
- VEC-830K (18 pages)
- VEC-841K (27 pages)
- VEC-830KC (26 pages)
- VEC-821KC (5 pages)
- VEC-830KC (6 pages)
- VEC-884 (76 pages)
- VEC-1010K (31 pages)
- VEC-1340K (35 pages)
- VEC-1340K (27 pages)
- VEC-1340K (21 pages)
- VEC-1380K (39 pages)
- VEC-1012K (29 pages)
- VEC-1016K (23 pages)
- VEC-102K (37 pages)
- VEC-1180K (35 pages)
- VEC-131K (35 pages)
- VEC-121K (31 pages)
- VEC-1613 (4 pages)
- VEC-221K (35 pages)
- VEC-412K (35 pages)
- VEC-1500K (68 pages)
- VEC-422K (27 pages)
- VEC-483K (17 pages)
- VEC-603 (2 pages)
- VEC-814 (4 pages)
- VEC-8218K (18 pages)
- VEC-841W (5 pages)
- VEC-862 (5 pages)
- CK-200 (8 pages)
- PMT-228 (20 pages)
- VEC-162 (10 pages)
- VEC-202 (8 pages)
- VEC-204 (8 pages)
- VEC-254 (4 pages)