Multi Format LCD Monitor 25
●
●
Volume
- Used to control the output volume for the
internal speakers or [AUDIO OUT] on the
back of the monitor.
- Control range is from 0 to 30.
●
●
Em. Audio Left/Right
- Used to set embedded audio channel for
internal speaker or [AUDIO OUT] terminal on
the back of the monitor.
- In SDI mode one of the Off or CH1~CH16
can be selected. In HDMI(HDCP 1.1 Version)
mode, Left and Right are set to CH1 and CH2
respectively.
●
●
Level Meter
- Used to set the Level Meter for the
embedded audio.
- Available options are OFF, 16 CH(HOR.) and
16 CH(VER.)
- SDI Input : [Off]-[16CH(Hor.)]-[16CH(Ver.)]
- HDMI Input: [Off]-[2CH(Hor.)]-[2CH(Ver.)]
* 16 CH(HOR.) : Displays 8 channels on top
left and 8 channels on top right of the screen
horizontally.
* 16 CH(VER.) : Displays 8 channels on center
left and 8 channels on top right of the screen
vertically.
●
●
Level Meter Display
- Used to set the display method for audio
level meter.
- Available modes are Group and Pair.
- Activates only on SDI/HDMI input mode.
●
●
Level meter reference
- Display the default audio level meter value,
Available options are -18dB and -20dB.
- Audio level meter within selected value
turns to green and exceeded audio level is
displayed in yellow.
- Audio level exceeding -4dB is displayed in
red.
●
●
Level meter size
- Used to control the size of the audio level
meters.
- Available options are NORMAL and LAGRE.
●
●
Peak Decay Time
- Used to set the reduction time of the
maximum indication of audio signals.
- Available values are form 0 to 100. Larger
values indicate a longer time to display.
5. Menu Operations