beautypg.com

Menu operations, 6] audio – TVLogic LVM-174W User Manual

Page 25

background image

Multi Format LCD Monitor 25

Volume

- Used to control the output volume for the

internal speakers or [AUDIO OUT] on the

back of the monitor.

- Control range is from 0 to 30.

Em. Audio Left/Right

- Used to set embedded audio channel for

internal speaker or [AUDIO OUT] terminal on

the back of the monitor.

- In SDI mode one of the Off or CH1~CH16

can be selected. In HDMI(HDCP 1.1 Version)

mode, Left and Right are set to CH1 and CH2

respectively.

Level Meter

- Used to set the Level Meter for the

embedded audio.

- Available options are OFF, 16 CH(HOR.) and

16 CH(VER.)

- SDI Input : [Off]-[16CH(Hor.)]-[16CH(Ver.)]

- HDMI Input: [Off]-[2CH(Hor.)]-[2CH(Ver.)]

* 16 CH(HOR.) : Displays 8 channels on top

left and 8 channels on top right of the screen

horizontally.

* 16 CH(VER.) : Displays 8 channels on center

left and 8 channels on top right of the screen

vertically.

Level Meter Display

- Used to set the display method for audio

level meter.

- Available modes are Group and Pair.

- Activates only on SDI/HDMI input mode.

Level meter reference

- Display the default audio level meter value,

Available options are -18dB and -20dB.

- Audio level meter within selected value

turns to green and exceeded audio level is

displayed in yellow.

- Audio level exceeding -4dB is displayed in

red.

Level meter size

- Used to control the size of the audio level

meters.

- Available options are NORMAL and LAGRE.

Peak Decay Time

- Used to set the reduction time of the

maximum indication of audio signals.

- Available values are form 0 to 100. Larger

values indicate a longer time to display.

5. Menu Operations