15.2.7.4 CueType Node [optional]
The CueType element corresponds to the type of Cue used by the TriggerCue. The available
Cue Types are listed in the table below:
Table 3: Cue Types Available
Type
Description
GPI
Allows assignment of a GPI line and value to the Trigger
Signal
Allows assignment of another signal to the Trigger
15.2.7.5 CueTypeParameters [optional]
The CueTypeParameters element contains the parameters associated to the Cue type defined
in the CueType element (Figure 57).
Figure 57: TriggerCue Structure
Dotted lines denote optional elements that can be omitted during the creation based on
the Macro Editor.
For GPI Cue Type, the two following parameters have to be used:
Line and Value.
The Line element specifies the GPI line number to be used for the associated command. It
contains an integer to be chosen between 0 and 7.
The Value element indicates the state of the GPI: ON (Value = 1) or OFF (Value = 2).
For Signal Cue Type, the following parameter has to be used: Name.
The Name element specifies the signal name.