Installation introduction, 9 cabling connection, 10 electrification inspection – AVUE G55IR-WB36N – Outdoor 36X Long Range IR PTZ User Manual
Page 54
Please make video cable, power cable, control cable
and alarm cable penetrated the bracket, and fixed
the bracket stably. Keep enough length of cables:
Video cable should be kept 50 mm out of the bracket ,
and other cables should be kept 80-100 mm from the
bracket.
Lock 4 pieces of M8 screw and fix the bracket on the wall,
then smear the glass pastern on the joint side between
wall and the bracket pad which passed the line in order
to prevent the water entering. (Refer to below picture)
Picture 11.8-6
Glass pastern
:
AQUA: NC2
BROWN: NO2
GRAY: ALM7
PURPLE: ALM6
ORANGE: ALM5
Alarm terminal 2
Alarm terminal 1
:
RED: ALM1
PINK: ALM2
YELLOW: ALM3
GREEN: ALM4
BLACK: COM
WHITE: NO
BLUE: NC
RS485 terminal
:
YELLOW:RS485-
GREEN:RS485+
Power supply terminal
:
RED:AC24V+
YELLOW: GROUNDING
BLACK:AC24V-
Picture11.9-1
11.9 Cabling Connection
Please connect cables refer to the attached tag. Detail
connection refer to below list.
11.10 Electrification inspection
Connect video cable and control cable to the other
equipments; Electrify 24VAC power.
The PTZ carries on self-checking and executes
replacement procedure after power-on.
In the process of self-checking, camera will rotate
horizontally and slowly for one and half cycle to the
default original horizontal point which is set by factory,
then upwardly turn to original vertical point, then
downwardly to original horizontal point. Lens will be
pulled from far focus to near focus to complete self-
checking. The whole camera is absolutely steady means
PTZ completed self-checking and ready to be controlled.
If unstable, please refer to the troubleshooting in the
operation manual appendix.
Picture11.8-5
01Cabling
02Inflation screw
03Bracket
1
2
3
4
5
1. Alarm terminal 2
2. Video connector
3. Alarm terminal 1
4. RS485 terminal
5. Power supply terminal
Yellow
Black
Red
Connection drawing of Infrared LED
Picture11.9-2
According to different night-vision function, you can refer
to the following connection drawing:
1. Alarm terminal 2
2. Video connector
3. Alarm terminal 1
4. RS485 terminal
5. Power supply terminal
6.Searchlight power supply
Red
AC24V+
“
”
Black AC24V-
“
”
Red
Yellow
Black
5
6
1
2
3
4
NOTE:5and 6 should connect with a AC24V adaptor individually.
Connection drawing of Searchlight
51
Installation Introduction