beautypg.com

Alarm function alarm function – AVUE G55IR-WB36N – Outdoor 36X Long Range IR PTZ User Manual

Page 37

background image

8. Alarm function

Alarm Function

AUX2

GND

1

2

3

4

5

6

7

ALARMS

AUX1

earthing

Alarm input 1-7bits

Alarm ouput 1

Alarm output 2

The PTZ may connect with 7 alarm input, 2 alarm output, and support ala-

rm linkage. The external alarm message sends to the PTZ, then the PTZ sends to
alarm point shoot (to call preset, auto scan, auto cruise and auto pattern), and choose
that to run alarm output or not.

The system enters into the main menu by calling 95 preset or by calling 9 preset

twice within 3 seconds. click each menu according to the left picture, then enter m-
enu alarm, choices as follow:

alarm number is corresponding with 12 bits plug in

the external switching board of the PTZ (as below shows). 001 priority is
the highest, 007 priority is the lowest. The two lines alarm input at the sa-
me time, the PTZ run alarm that the highest priority.

as current alarm input, to run the action. Choices for

choosing as follow. NONE---none action/SCAN/PAT X---run a pattern tour
/TOUR---run tour/PRESET---call preset, when the PTZ number is set as 1,
to call preset 1; when the PTZ number is set as 2, to call preset2.

as current alarm input, to run alarm output or not. NO-

NE---none alarm output/AUX 1---the first alarm output/AUX 2---the sec-
retaryond alarm output/BOTH--- two alarms output.

ALARM PRIORITY alarm priority can be defined as three grades:

high, middle, low.

resume mode after relieving alarm input, there are two choi-

ces: ON---clear alarm output, the PTZ will stop.

OFF---just clear alarm output.

SEQUENCE The park time between two alarm in the same priority, the

range is 1-60s.

set alarm reset and delay the time (1-225s) how long

to relieve and run RESUME after the PTZ receives alarm message.

set state of the relay. N/C---often close the state,

N/O---often hold the state. If setting as often closing the state, the relay is
in closing the state when there is no alarm to output; when there is alarm to
output, the relay is in holding the state.

AL

to ALARM SETTING , press OPEN

to enter the menu alarm setting

1

ALARM CONTACT

ARM SETTING

ARM SETTING

2 Operate joystick, move the cursor

ALARM NUMBER

ALARM ACTION

ACTIVATE AUX

●【

●【

●【

●【

●【

●【

●【

●【

●【

●【

RESUME

RESET DELAY

ALARMS

RESUME

OFF

SEQUENCE

002

RESET DELAY

020

ALARM CONTACT N/C
ALARM SETTING
ARM SETTING
BACK
EXIT

ALARM SETTING

ALARM NUMBER

001

ALARM ACTION

TOUR

ACTIVATE AUX

NONE

ALARM PRIORITY

HIGH

BACK
EXIT

34

MAIN MENU

SYSTEM SETTING
CAMERA SETTING
FUNCTION SETTING
WINDOW BLANKING
ALARMS
LANGUAGE
EXIT