Warnings, Stuff preparation – AVUE G55IR-WB36N – Outdoor 36X Long Range IR PTZ User Manual
Page 51

This product uses TVS lightning Proof technology,
can prevent from the damage of the equipment caused by
kinds of pulse signal such as instant lightning strike of
power below 4000V, the surge and so on.
At the same time, you must adopt the essential prote-
ctive measure according to the actual situation regarding
outdoor installation under the guarantee electricity security.
(Refer to chapter 1.3 Distributing the line in security)
11. 3
11. 4
Lightning Proof and Surge Proof
Water Proof
11.5 The preparation of installation
Outdoor PTZ has well waterproof moisture-proof
dustproof performance, has achieved the IP66 international
standard.
All installation and maintenance work related this
product should complete by technical personnel who
have qualification of installation and maintenance.
Please refer to this handbook for detail.
All electrical work must be observe local latest
electricity laws, regulation on fireproof as well as
the related laws and regulations:
Checking everything is completed according to
packing list. Make sure the application place and
the way of installation for PTZ is coincide with
the request. If not, please contact your supplier.
Please use this product according to the working
conditions request.
Please handle with the pan/tilt module carefully,
do not extrude various structure parts; The down
cover belongs to the senior optics part, do not touch
with hand; Please do not get through power except
for the electrifying inspection in process of installation.
Make sure you have enough space to hold this product
and it's parts of installation in the site.
Make sure the bearing capacity of ceiling, wall,
bracket that installs the PTZ support the gross weight
of the PTZ and the structural parts of installation.
It is necessary to have the safe coefficient of 4 times
or above.
、
、
The indoor PTZ doesn't allowed to install in out-
door environment which is full of moisture and possibly en-
ter water. You should prevent the product and the internal
components from damage that caused by the long time water
-drop or spatter.
The request of the quality of installation
person and maintainer:
Basic requirements
Check the structure intensity for installation
space and installation site.
●
●
●
●
●
●
●
●
Ø
Ø
Ø
Warnings
Stuff Preparation
Please select the type of cables based on transmitting distance:
Minimum video coaxial cable requirements:
1)75 impedance
2)All copper conductor wire
3)95% copper net structure
●
Ω
Ø
RG59/U
750ft 229m
(
)
RG59/U
RG6/U
RG11/U
1,000ft 305m
(
)
1,500ft 457m
(
)
5C-2V
7C-2V
Domestic Gauge
International Gauge
Maximum Distance(ft/m)
●
●
RS485 Communication cables (Refer to manual appendix)
24VAC Power supply cable (Refer to manual appendix)
Please preserve the mode original package material
properly after opening the PTZ packing, in order to
mail the PTZ that is wrapped with original package
material to the agent or return it to the factory to repair
if problem occur.
It is likely to bring on the damage that caused by the
transport accident on the way if the mode uses the
non-original package material, and extra cost may
arise accordingly.
Mounting way of pan/tilt: wall mount, top-down
mount, stand-up mount.
Wall mount
The mounting place must bear four times weight of
PTZ/ mounting bracket and mounting base.
The wall place you choose for mounting site must be
stability and nothing to take off, and make sure the
bracket is mounted in the wall not the non-surface
object.
●
●
●
Stand-up mount
Top-down mount
The mounting place must meet the requirement of
chapter 1.3 distributing the line in security.
The pole bracket must be stability and no wobble.
The mounting position must undertake the weight of
pan-tilt.
Such a mounting way is only suitable for top-down type.
Otherwise, it would be water-leaking.
Ø
Keep All the Original Package Materials
Ø
Brief introduction of mounting way
48