System setting, Power up action, Fan startup by temperature – AVUE G55IR-WB36N – Outdoor 36X Long Range IR PTZ User Manual

Page 16: 5. 3 park action

background image

Power up action

This setting allows the PTZ to run an appointed action after it enters

vacancy for a few time (1-240minutes). If default sets as 0, it means not to
run this action automatically.

1

Operate joystick, move the cursor to PARK TIME , press OPEN

to tilt up/down joystick to set park time, the range is 0-240 (minute), press

OPEN

to save. PARK ACTON is running action at park time, when

PARK TIME sets as 0, this item can't be set.

2 Operate joystick, move the cursor to PARK ACTON , press OPEN
there will be a sign

in the front of PARK ACTON , the cursor jump

to right, after tilt up/down joystick to choose park action

there are

options for choosing as follow, press OPEN to save.

none action

use preset 1-80

run scan
run pattern X

run tour

The PTZ start to run actions after self-testing, if nobody intervenes
it , it will repeatedly run this action continuously , if default sets as

NONE .

1. Operate joystick, move the cursor to POWER UP ACTION : press

OPEN

to jump to the following choice, tilt up/down joystick to choose

power up action , press OPEN to save.

run scan

run pattern

run tour

none action

the PTZ resumes the primary action and direction

before power up.

use preset 1

NONE - (default)
PRESET -
SCAN -
PAT1 -
TOUR -

NONE

-

AUTO

-

PRESET -
SCAN -
PAT1 -
TOUR -









4. 5. 4

4. 5. 5

O

O

C.

C.【

TEMP can

switch the temperature between fahrenheit and centigrade.

Fan startup by temperature

The temperature of the PTZ will rise when it is in high temperature. The

fan will open automatically when the temperature reaches to a very high degree
value in order to make sure the stability of the PTZ.

Operate joystick, move the cursor to FAN ENABLED : press O-

PEN , the cursor will skip to the back option. The user can choose the fan
to start up temperature, and press OPEN to save it in actual condition.

The default setting temperature of the fan startup is 40

The user

also can enter into the fan startup setting to adjust the temperature of fan
startup. As picture shows: the temperature range is 0-60

4. 5. 3 Park action

System setting

13

MOTION

AUTO FLIP

ON

PROPORTION PAN ON
PARK TIME

005

PARK ACTION

SCAN

POWER UP ACTION AUTO

BACK
EXIT

FAN ENABLED

040

TEMP C/F

CENT

ADVANCE SETTING

MOTION

AUTO FLIP

ON

PROPORTION PAN ON
PARK TIME

005

PARK ACTION

SCAN

POWER UP ACTION AUTO

BACK
EXIT

FAN ENABLED

040

TEMP C/F

CENT

ADVANCE SETTING

MOTION

AUTO FLIP

ON

PROPORTION PAN ON
PARK TIME

005

PARK ACTION

SCAN

POWER UP ACTION AUTO

BACK
EXIT

FAN ENABLED

040

TEMP C/F

CENT

ADVANCE SETTING