5/2/2012
Do not connect the outputs to more than 30VDC. The current through each output terminal
must not exceed 100 mA.
PLC
STAC6-Si
STAC6-QE
12-24 VDC
Power Supply
+
–
OUT-
OUT+
IN
COM
Connecting output as a sourcing output.
STAC6-Si
STAC6-QE
OUT-
OUT+
5-24 VDC
Power Supply
+
–
Load
Connecting outputs as a sinking output.
STAC6-Si
STAC6-QE
OUT-
OUT+
1N4935 suppression diode
5-24 VDC
Power Supply
+
–
relay
Using output to control a relay.