Connecting AC Power
Using the connector supplied connect to the AC supply per the diagram below. Use 16 AWG wire for Line
(L) and Neutral (N). Use 14 AWG for Earth Ground (G).
Care should always be taken when working with high voltages.
In regions where the single-phase supply is higher, an auto transformer can be used to drop the voltage to
the correct level.
Fusing
The STAC6 contains an internal 8A fast acting fuse. The STAC6-220 contains an internal 3.5A slo-blo (time
delay) fuse. If an external fuse is desired, we recommend a 6A fast acting fuse for the 120V STAC6 and a 5
amp fast acting fuse for the 220V version.
Line Filter
For applications requiring CE EMC compliance, a Corcom 6ET1 line filter is required in series with the AC
input.
To Earth Ground
To Neutral
To Line (Hot)
green
black or bro
wn
white or blue
AC Power Plug