34 stac6 hardware manual, Stac6 – Applied Motion STAC6-C User Manual
Page 34
34
STAC6 Hardware manual
920-0029 Rev. C
5/2/2012
Diagrams of different connections follow.
Do not connect the outputs to more than 30VDC.
The current through each output terminal must not exceed 100 mA.
STAC6
YCOM
Y1..Y3
5-24 VDC
Power Supply
+
–
Load
STAC6
YCOM
Y1..Y3
1N4935 suppression diode
5-24 VDC
Power Supply
+
–
relay
This manual is related to the following products: